What application support is available when developing a Scout bilayer assay?

We provide an introduction matched to your experience and free lifetime support by email, telephone or video call for applications, data analysis and technical questions.

Last update on 2026-11-18 by Frank Schaub.

Does Scout support investigations of lipid phase transitions as well as pore-forming proteins?

Yes. Scout lists lipid phase transitions alongside ion channels and nanopores among its applications, with conductance and capacitance as membrane readouts.

Last update on 2026-11-18 by Frank Schaub.

Which steps in a planar lipid bilayer experiment are automated by Ionovation Scout?

Scout automates bilayer formation, validation and data acquisition. It also monitors membrane properties and provides online analysis during electrophysiological experiments.

Last update on 2026-11-18 by Frank Schaub.

Can Scout detect membrane-active effects beyond discrete ion-channel openings?

Scout detects changes in lipid-membrane conductance and capacitance. Its listed applications include nanopores, toxins, transporters, ionic liquids and lipid phase transitions.

Last update on 2026-11-18 by Frank Schaub.

Can Scout combine bilayer electrophysiology with controlled-temperature experiments?

Scout is compatible with Ionovation Thermomaster 2 for temperature-controlled lipid-bilayer experiments.

Last update on 2026-11-18 by Frank Schaub.

FAQ-Explorer

How does Explorer combine optical access with free-standing lipid bilayer electrophysiology?

Explorer forms horizontal free-standing bilayers on an inverted microscope, combining electrophysiology with high-resolution microscopy and single-molecule spectroscopy.

Last update on 2026-11-18 by Frank Schaub.

Can Explorer perfuse both cis and trans compartments while retaining optical access?

Yes. Explorer provides perfusion on both sides of the horizontal membrane. ExplorerSlides contain microchannels for fluid exchange in the cis and trans compartments.

Last update on 2026-11-18 by Frank Schaub.

When is the Explorer Capmeter configuration appropriate instead of an electrophysiology amplifier?

Capmeter supports automated membrane formation and monitoring when current measurements through channels or pores are unnecessary. It replaces the electrophysiology amplifier in that configuration.

Last update on 2026-11-18 by Frank Schaub.

Can Explorer support ligand-binding studies at predefined membrane potentials?

Yes. Explorer lists binding studies at predefined membrane potentials and investigations relating ligand binding to ion flux among its applications.

Last update on 2026-11-18 by Frank Schaub.

Which aperture sizes are available for ExplorerSlide bilayers?

ExplorerSlides are offered with apertures from 70 to 300 µm, with 120 µm listed as standard.

Last update on 2026-11-18 by Frank Schaub.

Which optical methods are identified for Explorer membrane experiments?

Explorer identifies FCS, TCSPC and FRET as compatible microscopy approaches, and lists Raman studies of artificial membranes among its applications.

Last update on 2026-11-18 by Frank Schaub.

FAQ-FCS-easy

Which excitation wavelengths and timing hardware are specified for FCS-easy?

FCS-easy lists 488 nm and 633 nm confocal excitation, with continuous-wave or pulsed operation, and a Swabian Instruments time-tagging module for TCSPC.

Last update on 2026-11-18 by Frank Schaub.

Are confocal imaging and fluorescence-lifetime measurements standard FCS-easy functions?

Confocal imaging and fluorescence-lifetime measurements are listed as optional FCS-easy capabilities.

Last update on 2026-11-18 by Frank Schaub.

Which microplate formats does FCS-easy support for automated interaction screening?

FCS-easy lists motorized-stage support for 96-, 384- and 1536-well plates, with automated serial measurements for binding, competition, kinetics and affinity screening.

Last update on 2026-11-18 by Frank Schaub.

FAQ-PicoTweezers

How does PicoTweezers detect forces in three dimensions?

PicoTweezers uses real-time video-based force detection, with sub-piconewton resolution stated for its three-dimensional measurements.

Last update on 2026-11-18 by Frank Schaub.

How does the PicoTweezers optical layout accommodate microfluidic sample chambers?

Force detection and laser control sit below the trapping objective, leaving space above the trap for carriers such as microfluidic cartridges and microplates.

Last update on 2026-11-18 by Frank Schaub.

Which microscopy extensions are listed for PicoTweezers?

PicoTweezers can be extended to fluorescence, STED, Raman, TIRF and confocal approaches, including time-resolved confocal microscopy.

Last update on 2026-11-18 by Frank Schaub.

Is PicoTweezers available in single-trap and dual-trap configurations?

Yes. PicoTweezers is offered as a single- or dual-beam optical tweezers system on an inverted microscope platform.

Last update on 2026-11-18 by Frank Schaub.

Which force-spectroscopy applications are described for PicoTweezers?

Listed applications include protein folding, receptor–ligand interactions, DNA stretching, controlled nanopore translocation and microrheology, including work in microfluidic environments.

Last update on 2026-11-18 by Frank Schaub.

FAQ-Publications

Which listed publications address combined single-molecule imaging and bilayer electrophysiology?

Our bibliography includes Weatherill and Wallace (2015), on combining single-molecule imaging with single-channel electrophysiology in the Journal of Molecular Biology.

Last update on 2026-11-18 by Frank Schaub.

Which listed references are relevant to diffusion and phase organization in model lipid membranes?

Our bibliography includes Honigmann and colleagues (2010) on horizontal-bilayer phase separation, and studies by Weiß and colleagues on dual-focus FCS measurements of lipid and membrane-protein diffusion.

Last update on 2026-11-18 by Frank Schaub.

FAQ-Q-Pac / Q-Pack

What does Q-Pac measure optically in label-free cell analysis?

Q-Pac uses interferometry to measure sample-induced optical-path-length changes across the field, providing quantitative phase images without scanning.

Last update on 2026-11-18 by Frank Schaub.

Can Q-Pac refocus phase images numerically after acquisition?

Yes. Q-Pac lists subsequent numerical refocusing and autofocusing as part of its quantitative phase-imaging approach.

Last update on 2026-11-18 by Frank Schaub.

Can Q-Pac follow cellular growth without fixed assay endpoints?

Q-Pac supports label-free time-lapse observation of cellular dynamics, including growth and mass changes over extended observations without fixed endpoints.

Last update on 2026-11-18 by Frank Schaub.

Which cell-migration readouts are identified for Q-Pac?

Q-Pac lists automated cell tracking with migration trajectories, motility and direction as readouts.

Last update on 2026-11-18 by Frank Schaub.

FAQ-Thermomaster

What temperature range is specified for Thermomaster bilayer experiments?

Thermomaster lists an approximate operating range of 10–50 °C for temperature-controlled experiments with Ionovation bilayer workstations.

Last update on 2026-11-18 by Frank Schaub.

Does Thermomaster record chamber temperature alongside current and voltage?

Yes. Thermomaster measures temperature inside the bilayer chamber and records a parallel temperature trace associated with the electrophysiological data.

Last update on 2026-11-18 by Frank Schaub.

Can Thermomaster run automated temperature protocols through Patchmaster?

Yes. Thermomaster lists automated temperature protocols and control through Patchmaster scripts.

Last update on 2026-11-18 by Frank Schaub.

Can Thermomaster operate without an electrophysiology amplifier?

Yes. Thermomaster can operate independently to heat or cool a chamber or microscope stage without an electrophysiology amplifier.

Last update on 2026-11-18 by Frank Schaub.

Which temperature-dependent membrane processes can be investigated with Thermomaster?

Thermomaster supports experiments on channel activation kinetics, lipid-mixture melting behaviour, membrane-component diffusion and temperature-dependent protein interactions.

Last update on 2026-11-18 by Frank Schaub.

FAQ-Tools and consumables

Which premixed lipids are listed for Ionovation bilayer experiments?

The catalogue lists Soybean S4, dried POPE/POPC/POPS at 8:1:1, and dried DPhPC formulations.

Last update on 2026-11-18 by Frank Schaub.

Which ExplorerSlide variant is listed for Thermomaster experiments?

The catalogue identifies ExplorerSlide Thermo with a standard aperture for use with Thermomaster CEI100013.

Last update on 2026-11-18 by Frank Schaub.

Can I specify a custom POPC/POPE/POPS lipid mixture?

Yes. Bilayer-Lipid IV is listed as a custom mixture of POPC, POPE and POPS, with composition to be specified when ordering.

Last update on 2026-11-18 by Frank Schaub.

Are Scout and Explorer electrodes specified as separate consumables?

Yes. The catalogue lists electrode pairs for Scout/Compact separately from electrode pairs for Explorer, plus an Explorer electrode-filling device.

Last update on 2026-11-18 by Frank Schaub.

About us

Ionovation GmbH has a wealth of experience in microscopy and electrophysiology. Our product line includes the 2018 Nobel Prize winning optical tweezers technology as well as unique fluorescence and quantitative phase contrast microscopy in combination with organ-on-chip technologies. In addition, we offer automated workstations for lipid bilayer electrophysiology. We always deliver state-of-the-art technologies and services for your research projects.

Contact Form

Please add 8 and 7.

Get in touch

Ionovation GmbH
Gewerbepark 9 - 11
49143 Bissendorf
Germany

+49 (5402) 968 979 30

+49 (5402) 968 979 39

Copyright 2026. All Rights Reserved.

This Website is using cookies and Google Webfonts.

Privacy Imprint
You are using an outdated browser. The website may not be displayed correctly. Close